Battery : Cell Testing Up To 10 V

Overview

Cell Voltage up to 10V
Cell Current up to 2500A
Ability to test up to 96 cells with a single chassis.
Arbin offers battery testing systems for basic charge/discharge cycling, and simulating complex real-world applications such as drive profiles, telecom pulses, or other custom profiles.
Arbin’s Laboratory Battery Testing (LBT) series commercializes technology established during a 3‐year ARPA-E project developing ultra‐high precision testing systems. This product consists of independent potentiostat/galvanostat channels for testing batteries and other energy storage devices, and is intended to provide an economical solution for applications requiring high‐precision measurements and fast data sampling. All Arbin testing systems come with a PC preloaded with our MITS Pro and Data Watcher software for creating test profiles, real‐time data monitoring, and data plotting & analysis.

Primary Applications :

  • Electrochemistry, Battery & Supercapacitor Testing
  • Coulombic Efficiency (HPCE) Measurements (HPT or MSTAT series is recommended)
  • Electric Vehicle (EV) Cell Testin
  • Life Cycle Testing
  • EIS (electrochemical impedance spectroscopy)

Key Features:

  • Fully independent high precision test channels with full potentiostatic, galvanostatic control
  • Allows integration with an approved EIS module for 10uHz to 2MHz measurements without changing connection.
  • Each channel provides 4 or more current ranges with industry‐leading 24‐bit resolution
  • Powerful embedded controllers provide fast data logging (2000 points per second, per system ) and control flexibility for the most advanced test requirements
  • Any number of channels can be operated in parallel for increased current‐handling capacity
  • Uses true Bipolar Linear circuitry providing cross‐zero linearity and zero switching time between charge and discharge
  • Systems are air-cooled with variable speed fans so no additional facility infrastructure or regular maintenance is needed.
  • Arbin’s advanced software package, MITS Pro, provides flexible scheduling, a user‐friendly interface, distributed system control, data acquisition, management, & analysis
  • Software provides easy data analysis and plotting based in Data Watcher and Microsoft Excel
  • A wide array of auxiliary inputs/outputs are available for additional data collection or control such as temperature monitoring, additional reference electrodes, and more

Safety:

  • Multiple levels of fusing are provided inside the system for protection as the channel/board and power supply levels.
  • Each channel module has a fully redundant microcontroller dedicated for safety monitoring.
  • Arbin’s software has safety functions for entire tests, and for individual steps within a test to help the user avoid overcharging, over‐discharging, over‐heating, etc.
  • Tests begin with a built‐in safety check of all control values.

 

Description

Specifications :

Measurement Resolution: 24-bit (1 part in 16,777,216)
Measurement Precision: <25ppm or <100ppm
Control Accuracy: <0.01% or <0.02%
Minimum Step Time: 5ms
Data Logging Rate: 2000 points per second, per system
Connection for PC: TCP/IP (Ethernet)
Ventilation Method: air-cooled with variable speed fans

Model Voltage Range Current Ranges Model Voltage Range Current Ranges
HPT-100mA 0 to 5V 100mA/10mA/1mA/100uA PHPT-50A 0 to 5V 50A/10A/1A/100mA
HPT-1A 0 to 5V 1A/100mA/10mA/1mA PHPT-200A 0 to 5V 200A/50A/10A/1A/100mA
HPT-5A 0 to 5V 5A/1A/100mA/10mA NOTE: All HPT models can achieve better than 50ppm CE precision
LBT ±5V – 200mA (-5) to 5V 200mA/10mA/1mA/100μA LBT 5V – 30A 0 to 5V 30A/5A/500mA/20mA
LBT ±5V – 1A (-5) to 5V 1A/50mA/2mA/100μA LBT 5V – 60A 0 to 5V 60A/5A/500mA/20mA
LBT ±5V – 5A (-5) to 5V 5A/500mA/20mA/1mA LBT 5V – 100A 0 to 5V 100A/10A/1A/100mA
LBT ±5V – 10A (-5) to 5V 10A/500mA/20mA/1mA LBT 5V – 250A 0 to 5V 250A/50A/5A/500mA
LBT 5V – 5A 0 to 5V 5A/500mA/20mA/1mA LBT 5V – 300A 0 to 5V 300A/50A/5A/500mA
LBT 5V – 10A 0 to 5V 10A/500mA/20mA/1mA LBT 5V – 500A 0 to 5V 500A/50A/5A/500mA

Arbin Instruments provides a wide variety of auxiliary modules for expanding the capability of the main charge/discharge control circuitry. Modules can either be placed in the main chassis, or in a small external chassis. This also makes it easy to add auxiliary options to existing systems.

Arbin offers an EIS Interface for approved 3rd party EIS modules for customers who wish to perform electrochemcial impedance spectroscopy experiments.  The EIS Interface allows a single EIS module to be shared across up to 32 channels; fully maximizing the duty cycle of EIS station and Arbin tester.  No change in connection is necessary.Frequency range of 10uHz to 2MHz.
Arbin offers Auxiliary Voltage Inputs that can be used as additional reference electrodes in a multi-electrode experiment.  Data logged from auxiliary voltage inputs can be flexibly assigned by the user to one, many, or all of the main charge/discharge channels.  Measurements can be used to control the test, act as safety limits, or simply record data.
Temperature Measurement Inputs are offered for Type-T or K Thermocouple, or 10kohm or PT100 Thermistor sensors.  Temperature data logged from these inputs can be flexibly assigned by the user to one, many, or all of the main charge/discharge channels.  Temperature can be used to control the test, act as safety limits, or simply record temperature measurements.

Arbin MZTC Battery Test Chamber

Arbin’s Cell-Isolating Thermal Safety Chamber (MZTC) is a battery test chamber with 8 independent temperature chambers in 1.  Insulation and protection between each chamber provides greater temperature control and a safe testing environment by isolating each cell or set of cells, as well as making connections easy.

Arbin EV battery pack tester

Arbin EV Battery Pack Tester with Chamber

This module allow’s the Arbin tester to interface with approved 3rd party temperature/environmental chambers from other manufacturers.  The Arbin software can turn the chamber on/off and adjust temperature during testing.  Temperature setpoints from the chamber controller are automatically logged in the data and independent temperature measurements are available using thermocouple or thermistor inputs.

Digital and Analog Input/Output channels are offered to interact with external hardware devices.
— The Digital I/O will send and receive a simple on/off, high/low relay signal.  It can activate a BMS, receive a confirmation signal, and many other options.
— The Analog I/O will control any device that operates in a 0(2)-10V signal such as pumps, valves, etc.
Arbin’s Auto-Calibration module allows channels to be calibrated automatically with connected to an appropriate source meter.  While the calibration interface is built into the software for all systems, this module removes the need for human involvement in the process and is recommended for systems with channel quantities greater than 32.
The Uninterrupted Power Supply (UPS) option will provide backup power to the PC with your Arbin system.  It allows the test to automatically pause and wait for power to be restored to the tester and will automatically and safely resume testing after brief outages.  Otherwise, the software and PC will safely be shut down.
A variety of Battery Holders and Racks are available for coincells, cylindrical cells, pouch/flat cells, and more.  These individual holders are available for currents up to 300A.  The wheeled battery racks make it easy to organize large quantities of cells with removable trays and cable organization.
The Redundant Safety Monitoring System (RSMS) can be placed in series with any battery tester including those from USA, Europe, and Asia.  The RSMS allows users to set a limit for Voltage, Current, Power, and Temperature that will automatically disconnect the battery or device under test is a safety limit is reached.  Many manufacture’s claim to have comprehensive safety features, but the RSMS guarantees and extra layer of protection to help prevent failure events.

 

 

Reviews