IGBT7000-100V200A

Overview

Neware technology limited founded in 1998, one of the best battery testing system researchers and manufacturers in China.

As a leader of battery testing solutions provider founded in 1998, Neware has been committed to providing world-class battery testing products and services for the last 21 years. In fact, these efforts have been rewarded with more than 180,000 sets of testing equipment sold to over 26,000 customers, ranging from battery / capacitor manufactures (production, quality control)and automakers to R&D institutes across the world.

 

Category:

Description

Specifications :
AC input voltage : AC 380 V ± 10 %/50 Hz
Output power : 40 KW
Input current : 68 A/Phase
Input power : 44 KW
Voltage : Constant voltage 10 V – 100 V
: Min discharge voltage 10 V
: Accuracy ± 0.1 %  of  FS
: Stability ± 0.1 % of  FS
Current : Output range 1 A – 200 A
: Accuracy ± 0.1%  of  FS
: CV cut-off current 1 A
: Stability ± 0.1%  of  FS
Power : Max output power/CH 20 KW
: Stability ±0.2 %  of  FS
Response time : Current response time Maximum 10 ms
: Step response time ≤ (365*24) hour/step , Time format : 00:00:00.000 (h,m,s,ms)
Data record interval : Minimum record interval:100 ms
: Minimum voltage record interval: 0.2 V
: Minimum current record interval: 0.4 A
: Max frequency 10Hz
Charge mode : Constant current, Constant voltage, Constant current and voltage, Constant power
Charge Cut-off : Main channel : Voltage , Current , Δ T,  Δ Capacity , Δ V
Discharge mode : Constant current , Constant power , Constant resistance
Discharge Cut-off : Main channel : Voltage , Current , ΔT , Δ Capacity
SIM : Charge mode Current, Voltage
: Discharge mode Current, Voltage
: Cut-off Time, Command line number
: Charge and discharge switch Yes
: Max SIM command lines 1,000,000
Cycle : Cycles Max 65535
: Steps for each cycle Max 254
: Nest for each cycle Max 3
Software Protection : Power-off data protection
: Off-line operation mode
: User-defined protection conditions, such as upper and lower
  limited current/voltage, delay time, temperature, etc.
Channels Feature : Independent pairs of closed loop for constant current source
  and constant voltage source.
Energy saving : Discharge energy can be returned to power grid
Channels working mode : Independent control
Parallel mode : Yes
Noise : <75 dB
Database : MySql
Communication protocol : TCP/IP
Data export : EXCEL , TXT , CSV , PDF , PLOT / GRAPH
Harddrive requirement : 500 GB
Operating system : Windows 7/8/10 64 bit
Communication port : Ethernet port
Channel numbers : 2
Dimension(W*D*H) : 1350 × 1000 × 1750 mm
Weight : 650 kg
Operation and storage environment requirement
Operation environment temperature : 0℃ – 40 ℃ (When the temperature is 25 ± 10 ℃ , the accuracy bias
  caused by temperature change is less than 50 ppm / ℃)
Storage environment temperature : -10 ℃ – 50 ℃
Operation environment humidity : ≤ 70 % RH (no moisture condensation)
Storage environment humidity : ≤ 80 % RH (no moisture condensation)
Aux channels : Aux types  : Temperature , Voltage
( Optional ) : Temperature range  -25 ℃ – 110 ℃
: Temperature accuracy  ± 1 ℃
: Temperature resolution 0.1 ℃
: Voltage range  -5 V – 5 V
: Voltage accuracy  ±  0.1 %  of  FS
Temperature aux channels for each : Up to 248
mainchannel(Optional)
Voltage aux channels for each main : Up to 248
channel(Optional)
Protection settings for aux channels : Temperature up-limit, bottom-limit; Voltage up-limit, bottom- limit ; ΔV of single cell.
Included 1. Ethernet cable: 1 pc (1m/ 2m/ 3m/ 5m)
2. Cable connector: 2 pcs (0.25m/ 0.5/ 1m/ 2m/ etc)
3. Clamp : 2 pcs ( Alligator/ Polymer/ Ring Connector )
4. Power cable: 1 pc
5. AZUS LAPTOP -ASUS Notebook X441UB-GA502T

 

Download Brochure IGBT7000-100V200A

Reviews

There are no reviews yet.

Be the first to review “IGBT7000-100V200A”

Your email address will not be published. Required fields are marked *